求救:solaris9 系统日志报错,请高手帮忙分析一下。
以下是系统日志报错:请高手帮忙分析。
Apr 19 10:43:34 db2 genunix: [ID 408789 kern.warning] WARNING: ce1: fault detected external to device; service degraded
Apr 19 10:43:34 db2 genunix: [ID 451854 kern.warning] WARNING: ce1: xcvr addr:0x01 - link down
Apr 19 10:43:34 db2 in.mpathd[1821]: [ID 215189 daemon.error] The link has gone down on ce1
Apr 19 10:43:39 db2 genunix: [ID 408789 kern.notice] NOTICE: ce1: fault cleared external to device; service available
Apr 19 10:43:39 db2 genunix: [ID 451854 kern.notice] NOTICE: ce1: xcvr addr:0x01 - link up 100 Mbps full duplex
Apr 19 10:43:39 db2 in.mpathd[1821]: [ID 820239 daemon.error] The link has come up on ce1
Apr 19 10:43:53 db2 in.mpathd[1821]: [ID 620804 daemon.error] Successfully failed back to NIC ce1
Apr 19 10:43:53 db2 in.mpathd[1821]: [ID 299542 daemon.error] NIC repair detected on ce1 of group ipmp1
Apr 24 04:20:40 db2 cl_eventlogd[1806]: [ID 848580 daemon.error] Restarting on signal 1.
Apr 24 04:20:40 db2 cl_eventlogd[1806]: [ID 758663 daemon.error] Unexpected failure encountered.
May 1 04:20:40 db2 cl_eventlogd[1806]: [ID 848580 daemon.error] Restarting on signal 1.
May 1 04:20:40 db2 cl_eventlogd[1806]: [ID 758663 daemon.error] Unexpected failure encountered.
如果你对这篇内容有疑问,欢迎到本站社区发帖提问 参与讨论,获取更多帮助,或者扫码二维码加入 Web 技术交流群。
绑定邮箱获取回复消息
由于您还没有绑定你的真实邮箱,如果其他用户或者作者回复了您的评论,将不能在第一时间通知您!
发布评论
评论(5)
自己先顶下,别沉了
It look like ce11 network problem that occur the message on Apr.19.
About nn Apr 24 and May 1 message that can reference http://cn.forums.oracle.com/forums/thread.jspa?threadID=1952138
Some part describe as below:
Bug ID: 6233626
Synopsis: SC 3.1: Messages "Unexpected failure encountered" reported by daemon "cl_eventlogd" lack clarity.
The bug describes situation that leads to this. The message can be ignored.
Thank you!
Don't mention. I hope my explain is helpful.
楼上正解啊