V490启动出现以下信息,prtdiag -v等命令下看,内存都没问题,谁告诉下,是内存还是CPU有问题
root@V490 # fmadm faulty
--------------- ------------------------------------ -------------- ---------
TIME EVENT-ID MSG-ID SEVERITY
--------------- ------------------------------------ -------------- ---------
May 11 17:35:05 f18f5a8a-3ff2-c035-ddc1-8250b1450d43 SUN4U-8007-L3 Critical
Host : V490
Platform : SUNW,Sun-Fire-V490 Chassis_id :
Fault class : fault.memory.dimm-ue-imminent 95%
Affects : mem:///unum=Slot,A:J7900
faulted but still in service
FRU : mem:///unum=Slot,A:J7900 95%
faulty
Serial ID. : 397296
Description : A pattern of correctable errors has been observed suggesting the
potential exists that an uncorrectable error may occur.
Refer to http://sun.com/msg/SUN4U-8007-L3 for more information.
Response : None at this time.
Impact : None at this time. However, the potential uncorrectable error
warrants proactive service action to avoid any unplanned system
outages.
Action : Schedule a repair procedure to replace the DIMM. Use fmadm faulty
to identify the DIMM to replace.
--------------- ------------------------------------ -------------- ---------
TIME EVENT-ID MSG-ID SEVERITY
--------------- ------------------------------------ -------------- ---------
May 11 17:19:51 89688870-10be-43e2-e2f4-d75048903504 SUN4U-8000-35 Critical
Host : V490
Platform : SUNW,Sun-Fire-V490 Chassis_id :
Fault class : fault.memory.bank 95%
Affects : mem:///unum=Slot,A:J7900,J7901,J8001,J8000
faulted but still in service
FRU : mem:///unum=Slot,A:J7900,J7901,J8001,J8000 95%
faulty
Serial ID. : 397296
183284
398065
928562
如果你对这篇内容有疑问,欢迎到本站社区发帖提问 参与讨论,获取更多帮助,或者扫码二维码加入 Web 技术交流群。
绑定邮箱获取回复消息
由于您还没有绑定你的真实邮箱,如果其他用户或者作者回复了您的评论,将不能在第一时间通知您!
发布评论
评论(9)
就是做完最大化自检,启动到系统后出现的情况
回复 3# 东方蜘蛛
大仙,这个是都是B0的内存,貌似不太可能4条都有问题吧
内存,换吧
correctable errors24小时只出现一次的话,oracle不给换的,继续观察吧
# fmdump -eV | grep unum
换 Slot,A:J7900
内存的问题很大的。
像是内存问题,做个最大化自检看看
mem:///unum=Slot,A:J7900,J7901,J8001,J8000 95%
fmdump -eV|tail -100