各位帮我看看这是什么原因造成的!

发布于 2022-09-01 20:09:32 字数 874 浏览 8 评论 3

Feb 13 20:53:16 dns-1 SC Alert: [ID 407615 daemon.error] SYS_FAN at FT0/FM1 has FAILED.
Feb 13 21:00:43 dns-1 SC Alert: [ID 407631 daemon.error] SYS_FAN at FT0/FM2 has FAILED.
Feb 13 21:00:43 dns-1 last message repeated 1 time
Feb 13 21:16:30 dns-1 SC Alert: [ID 407599 daemon.error] SYS_FAN at FT0/FM0 has FAILED.
Feb 13 21:26:41 dns-1 SC Alert: [ID 407631 daemon.error] SYS_FAN at FT0/FM2 has FAILED.
Feb 13 21:26:41 dns-1 last message repeated 1 time
Feb 13 21:35:18 dns-1 SC Alert: [ID 407615 daemon.error] SYS_FAN at FT0/FM1 has FAILED.
Feb 13 21:35:18 dns-1 last message repeated 1 time
Feb 13 21:42:15 dns-1 SC Alert: [ID 407631 daemon.error] SYS_FAN at FT0/FM2 has FAILED

硬件指示灯正常,prtdiag -v看到的也是ok  但是机器隔几天就自动重启一起一次,重启的时候就报上述错误    我查了下好像是个BUG,需要打补丁,但是我不确定,想请各位帮忙看看

如果你对这篇内容有疑问,欢迎到本站社区发帖提问 参与讨论,获取更多帮助,或者扫码二维码加入 Web 技术交流群。

扫码二维码加入Web技术交流群

发布评论

需要 登录 才能够评论, 你可以免费 注册 一个本站的账号。

评论(3

梦魇绽荼蘼 2022-09-04 15:03:18

LS的思路是对的

一人独醉 2022-09-04 11:47:37

sc下showfaults和showlogs之类的命令能否看到相关的信息?如果这个也有的话,有可能是接触不良等问题,如果没有,则去看看补丁之类的吧

海的爱人是光 2022-09-04 03:44:16

本帖最后由 yulemi 于 2010-02-21 10:58 编辑

这是prtdiag -v看到的信息

root@dns-1 # prtdiag -v
系统配置:  Sun Microsystems  sun4v Sun Fire T200
内存大小:8064 兆字节

================================ Virtual CPUs ================================

CPU ID Frequency Implementation         Status
------ --------- ---------------------- -------
0      1000 MHz  SUNW,UltraSPARC-T1     on-line  
1      1000 MHz  SUNW,UltraSPARC-T1     on-line  
2      1000 MHz  SUNW,UltraSPARC-T1     on-line  
3      1000 MHz  SUNW,UltraSPARC-T1     on-line  
4      1000 MHz  SUNW,UltraSPARC-T1     on-line  
5      1000 MHz  SUNW,UltraSPARC-T1     on-line  
6      1000 MHz  SUNW,UltraSPARC-T1     on-line  
7      1000 MHz  SUNW,UltraSPARC-T1     on-line  
8      1000 MHz  SUNW,UltraSPARC-T1     on-line  
9      1000 MHz  SUNW,UltraSPARC-T1     on-line  
10     1000 MHz  SUNW,UltraSPARC-T1     on-line  
11     1000 MHz  SUNW,UltraSPARC-T1     on-line  
12     1000 MHz  SUNW,UltraSPARC-T1     on-line  
13     1000 MHz  SUNW,UltraSPARC-T1     on-line  
14     1000 MHz  SUNW,UltraSPARC-T1     on-line  
15     1000 MHz  SUNW,UltraSPARC-T1     on-line  

======================= Physical Memory Configuration ========================
Segment Table:
--------------------------------------------------------------
Base           Segment  Interleave  Bank     Contains
Address        Size     Factor      Size     Modules
--------------------------------------------------------------
0x0            8 GB     4           2 GB     MB/CMP0/CH0/R0/D0
                                             MB/CMP0/CH0/R0/D1
                                    2 GB     MB/CMP0/CH1/R0/D0
                                             MB/CMP0/CH1/R0/D1
                                    2 GB     MB/CMP0/CH2/R0/D0
                                             MB/CMP0/CH2/R0/D1
                                    2 GB     MB/CMP0/CH3/R0/D0
                                             MB/CMP0/CH3/R0/D1

========================= IO 配置 =========================

            IO                                                                                         
Location    Type  Slot Path                                          Name                      Model   
----------- ----- ---- --------------------------------------------- ------------------------- ---------
IOBD/NET0    PCIE IOBD                /pci@780/pci@0/pci@1/network@0    network-pciex8086,105e         
IOBD/NET1    PCIE IOBD              /pci@780/pci@0/pci@1/network@0,1    network-pciex8086,105e         
IOBD/PCIE    PCIE IOBD                   /pci@780/pci@0/pci@9/scsi@0         scsi-pciex1000,56 LSI,1064E
IOBD/NET2    PCIE IOBD                /pci@7c0/pci@0/pci@2/network@0    network-pciex8086,105e         
IOBD/NET3    PCIE IOBD              /pci@7c0/pci@0/pci@2/network@0,1    network-pciex8086,105e         
IOBD/PCIX    PCIX IOBD              /pci@7c0/pci@0/pci@1/pci@0/isa@2                       isa         
IOBD/PCIX    PCIX IOBD              /pci@7c0/pci@0/pci@1/pci@0/usb@5       usb-pciclass,0c0310         
IOBD/PCIX    PCIX IOBD              /pci@7c0/pci@0/pci@1/pci@0/usb@6       usb-pciclass,0c0310         
IOBD/PCIX    PCIX IOBD              /pci@7c0/pci@0/pci@1/pci@0/ide@8          ide-pci10b9,5229         

========================= HW 修订 =======================================

系统 PROM 修订:
----------------------
OBP 4.29.1 2008/10/29 14:15

IO ASIC 修订版:
------------------
Location             Path                                          Device                         Revision
-------------------- --------------------------------------------- ------------------------------ ---------
IOBD/SAS-SATA-HBA                                  /pci@780                 SUNW,sun4v-pci     0
IOBD/SAS-SATA-HBA                            /pci@780/pci@0              pciex10b5,8532.bc   188
IOBD/SAS-SATA-HBA                      /pci@780/pci@0/pci@9              pciex10b5,8532.bc   188
IOBD/IO-BRIDGE                                     /pci@7c0                 SUNW,sun4v-pci     0
IOBD/PCI-SWITCH1                             /pci@7c0/pci@0              pciex10b5,8532.bc   188
IOBD/PCI-BRIDGE                /pci@7c0/pci@0/pci@1/pci@0,2                pciex8086,341.9     9
IOBD/GBE0                    /pci@780/pci@0/pci@1/network@0     pciex8086,105e.108e.105e.6     6
IOBD/GBE0                  /pci@780/pci@0/pci@1/network@0,1     pciex8086,105e.108e.105e.6     6
IOBD/GBE1                    /pci@7c0/pci@0/pci@2/network@0     pciex8086,105e.108e.105e.6     6
IOBD/GBE1                  /pci@7c0/pci@0/pci@2/network@0,1     pciex8086,105e.108e.105e.6     6
IOBD/SAS-SATA-HBA               /pci@780/pci@0/pci@9/scsi@0       pciex1000,56.1000.1000.2     2

============================ Environmental Status ============================
Fan sensors:
------------------------------------------------------------
Location                           Sensor         Status   
------------------------------------------------------------
0846NNN084:CH/FT0/FM0              RS             ok
0846NNN084:CH/FT0/FM1              RS             ok
0846NNN084:CH/FT0/FM2              RS             ok
0846NNN084:CH/FT2                  RS             ok

Temperature sensors:
------------------------------------------------------------
Location                           Sensor         Status   
------------------------------------------------------------
0846NNN084:CH/IOBD/IOB             T_CORE         ok
0846NNN084:CH/IOBD                 T_AMB          ok
0846NNN084:CH/MB/CMP0              T_TCORE        ok
0846NNN084:CH/MB/CMP0              T_BCORE        ok
0846NNN084:CH/MB                   T_AMB          ok
0846NNN084:CH/PDB                  T_AMB          ok

Current sensors:
------------------------------------------------------------
Location                           Sensor         Status   
------------------------------------------------------------
0846NNN084:CH/MB                   I_VCORE        ok
0846NNN084:CH/MB                   I_VMEML        ok
0846NNN084:CH/MB                   I_VMEMR        ok

Current indicators:
------------------------------------------------------------
Location                           Indicator      Condition
------------------------------------------------------------
0846NNN084:CH/IOBD                 I_USB0         ok      
0846NNN084:CH/IOBD                 I_USB1         ok      
0846NNN084:CH/FIOBD                I_USB          ok      

Voltage sensors:
------------------------------------------------------------
Location                           Sensor         Status   
------------------------------------------------------------
0846NNN084:CH/SC/BAT               V_BAT          ok
0846NNN084:CH/IOBD                 V_+1V5         ok
0846NNN084:CH/IOBD                 V_+1V8         ok
0846NNN084:CH/IOBD                 V_+3V3MAIN     ok
0846NNN084:CH/IOBD                 V_+3V3STBY     ok
0846NNN084:CH/IOBD                 V_+1V          ok
0846NNN084:CH/IOBD                 V_+1V2         ok
0846NNN084:CH/IOBD                 V_+5V          ok
0846NNN084:CH/IOBD                 V_-12V         ok
0846NNN084:CH/IOBD                 V_+12V         ok
0846NNN084:CH/MB                   V_+1V5         ok
0846NNN084:CH/MB                   V_VMEML        ok
0846NNN084:CH/MB                   V_VMEMR        ok
0846NNN084:CH/MB                   V_VTTL         ok
0846NNN084:CH/MB                   V_VTTR         ok
0846NNN084:CH/MB                   V_+3V3STBY     ok
0846NNN084:CH/MB                   V_VCORE        ok

LEDs:
------------------------------------------------------------
Location                           LED            State   
------------------------------------------------------------
0846NNN084:CH/FT0/FM0              SERVICE        off     
0846NNN084:CH/FT0/FM1              SERVICE        off     
0846NNN084:CH/FT0/FM2              SERVICE        off     
0846NNN084:CH/FT2                  SERVICE        off     
0846NNN084:CH/SYS                  ACT            steady  
0846NNN084:CH/SYS                  LOCATE         off     
0846NNN084:CH/SYS                  SERVICE        off     
0846NNN084:CH/SYS                  REAR_FAULT     off     
0846NNN084:CH/SYS                  TEMP_FAULT     off     
0846NNN084:CH/SYS                  TOP_FAN_FAULT  off     
0846NNN084:CH/HDD0                 SERVICE        off     
0846NNN084:CH/HDD0                 OK2RM          off     
0846NNN084:CH/HDD1                 SERVICE        off     
0846NNN084:CH/HDD1                 OK2RM          off     
0846NNN084:CH/HDD2                 SERVICE        off     
0846NNN084:CH/HDD2                 OK2RM          off     
0846NNN084:CH/HDD3                 SERVICE        off     
0846NNN084:CH/HDD3                 OK2RM          off     

============================ FRU Status ============================
Location                           Name      Status  
------------------------------------------------------
0846NNN084:CH/FT0/FM0              FAN       enabled  
0846NNN084:CH/FT0/FM1              FAN       enabled  
0846NNN084:CH/FT0/FM2              FAN       enabled  
0846NNN084:CH/FT2                  FAN       enabled  
0846NNN084:CH                      SC        enabled  
0846NNN084:CH                      IOBD      enabled  
0846NNN084:CH                      MB        enabled  
0846NNN084:CH/MB/CMP0/CH0/R0/D0    DIMM      enabled  
0846NNN084:CH/MB/CMP0/CH0/R0/D1    DIMM      enabled  
0846NNN084:CH/MB/CMP0/CH1/R0/D0    DIMM      enabled  
0846NNN084:CH/MB/CMP0/CH1/R0/D1    DIMM      enabled  
0846NNN084:CH/MB/CMP0/CH2/R0/D0    DIMM      enabled  
0846NNN084:CH/MB/CMP0/CH2/R0/D1    DIMM      enabled  
0846NNN084:CH/MB/CMP0/CH3/R0/D0    DIMM      enabled  
0846NNN084:CH/MB/CMP0/CH3/R0/D1    DIMM      enabled  
0846NNN084:CH                      PDB       enabled  
0846NNN084:CH                      FIOBD     enabled  
0846NNN084:CH                      SASBP     enabled  
0846NNN084:CH/PS0                  PS        enabled  
0846NNN084:CH/PS1                  PS        enabled  

============================ FW Version ============================
Version
------------------------------------------------------------
System Firmware 6.7.2_IDR141175-01  2009/03/09 16:

====================== System PROM revisions =======================
Version
------------------------------------------------------------
OBP 4.29.1 2008/10/29 14:15

Chassis Serial Number
---------------------
0846NNN084
root@dns-1 #