Fixed issues in 1912 LTSR CU3 编辑
Citrix Provisioning 1912 CU3 (1912.0.13)
Compared to: Provisioning 1912 LTSR CU2
Citrix Provisioning 1912 LTSR CU3 contains all fixes included in the 1912 LTSR initial release, CU1, CU2, plus the following, new fixes:
Citrix Provisioning console issues
In the Citrix Provisioning console, attempts to copy and paste target device properties by using a mouse might fail. [CVADHELP-15568]
In large VMware deployments, the Export Devices Wizard might take longer than expected to filter the compatible devices. [CVADHELP-16996]
Citrix Provisioning server issues
VDAs fail to start in scenarios where DNS name resolution and BDM are used with Infoblox DNS and DHCP. [CVADHELP-15724]
Changes to scheduled updates you make through vDisk Update Management do not take effect until you restart the Citrix PVS Soap Server service. [CVADHELP-16410]
The Citrix Provisioning virtual disk might be forced to reconnect intermittently by the server. [CVADHELP-16457]
After upgrading Citrix Provisioning Services from version 7.15 LTSR to version 1912 LTSR CU2, the available network interfaces might be missing from the TFTP configuration tool (Tftpcpl.cpl). [CVADHELP-16888]
Attempts to merge the vDisk versions to a base image might fail causing this error message to appear:
The parameter is incorrect. Error number 0xE00000057.
[CVADHELP-16921]
In large VMware deployments, the Export Devices Wizard might take longer than expected to filter the compatible devices. [CVADHELP-16996]
Citrix Provisioning target device issues
The PVS Device Service (BNDevice.exe) might consume a high percentage of CPU usage. [CVADHELP-14870]
When you configure UEFI PXE with DHCP Option 17 through a custom port, a target device might fail to start. [CVADHELP-16036]
Enabling Asynchronous I/O for a vDisk might cause the target device failover to fail. [CVADHELP-16717]
When you upgrade or install the Provisioning Services target drivers into a platform layer, the Script value under the registry key HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\Windows\CurrentVersion\Group Policy\Scripts\Startup might be incorrectly set to C:\Program Files\Citrix\Provisioning Services\CPVOfficeActivation.cmd. As a workaround, you must manually run the command c:\windows\setup\scripts\kmsdir\gposetup.cmd. [CVADHELP-16994]
With this fix, multiple partitions from multiple hard disks can be combined to create a vDisk in a BIOS VM. [CVADHELP-17404]