Upgrade the LOM firmware on a Citrix ADC MPX appliance 编辑
Upgrade the LOM firmware on a Citrix ADC MPX appliance
Citrix has automated the upgrade of LOM firmware within Citrix ADC MPX software. It is no longer necessary to know your hardware platform or download any LOM firmware.
Note
This procedure requires two reboots to complete and therefore a disruption in production traffic is expected. Citrix recommends that you perform the upgrade during a maintenance window. In a high availability setup, perform the upgrade on the secondary node to minimize disruption to production traffic. The
upgrade_bmc.sh
script is supported on the following platforms:
- MPX 5900
- MPX 8005
- MPX 8900
- MPX 11500
- MPX 11515
- MPX 14000
- MPX 15000
- MPX 22000
- MPX 25000
- MPX 26000
For information about upgrading the Citrix ADC appliance, see Upgrade and downgrade a Citrix ADC appliance
Note
If you cannot log into the LOM GUI on the MPX 5900, MPX 8900, MPX 15000, or MPX 26000, reset the LOM password by typing
shell
in the command prompt and thenipmitool user set password 2 <your preferred password>
after upgrade to 5.56 or 4.61.
Troubleshooting
Console redirection fails after upgrading the LOM to 4.61 on the MPX 5900 and MPX 8900 platforms or 5.56 on the MPX 15000 and MPX 26000 platforms.
Perform a unit reset from the Maintenance tab, which resets the BMC.