Troubleshoot App Dashboard 编辑
Troubleshoot App Dashboard
After you add an application in the App Dashboard, the dashboard immediately displays the app basic configuration details. The application analytics details such as app score, key metrics, and issues start to populate within a few minutes (approximately 10 to 15 minutes). For more information, see Applications.
You must ensure that there is no issue with metrics data flow (AppFlow collector or Analytics profile) from the Citrix ADC instance. You can get more information on AppFlow collector and analytics profile in this document.
This document describes the troubleshooting steps that you need to perform when:
You click an application, the analytics for the selected application do not display the required data even after the mentioned duration (10–15 minutes).
The CS or LB application is always indicating Gray color (Not Applicable status) in App Dashboard.
Note
The troubleshooting procedures mentioned in this document are only applicable to Content Switching and Load Balancing virtual servers.
Troubleshooting scenario
Application is licensed
You must ensure if the application is licensed.
- Citrix ADM - Navigate to Settings > Licensing & Analytics Config and verify if the application is licensed under Virtual Server License Summary. If the application is not licensed, see Manage licensing and enable analytics on virtual servers to license the virtual server.
Metrics collector is enabled
You must ensure if Metrics Collector is enabled in the Citrix ADC instance.
For Citrix ADC version 13.0 or later, Metrics Collector is enabled by default, after the ADC instance is successfully added in Citrix ADM. To ensure if metrics collector is enabled:
Navigate to Infrastructure > Instances. Under Instances, select the type of instance (for example, Citrix ADC VPX).
Select the Citrix ADC instance.
From the Select Action list, select Metrics Collector.
On the Configure Metrics Collector settings page, ensure if Enable option is selected. If not, select the Enable option and click OK.
After you enable metrics collector and if you are still not able to view the data, validate:
The AppFlow collector in Citrix ADC instance version 13.0 earlier than 47.x build.
The analytics profile in Citrix ADC instance build 47.x or later.
Citrix ADC instance earlier than 47.x builds
In Citrix ADC:
Run the following command to ensure if the collector is UP and running at Port 5563:
sh appflow collector af_collector_rest_<adm_receiver_ip>
If no collector is available, do an instance manual polling in Citrix ADM.
Navigate to Infrastructure > Network Function > Poll Now
Select the instance and click Start Polling.
If polling fails, remove the ADC instance from Citrix ADM and then add the ADC instance again. When you add the ADC instance, the collector gets added on ADC.
If the collector indicates Down status:
Ensure if SNIP is configured.
If SNIP is not configured, you must configure SNIP. For more information, see Configuring SNIP.
Ensure that if ADC instance is reachable to Citrix ADM.
You can validate by doing a ping test. Run
ping -S <SNIP> <adm_receiver_ip>
Citrix ADC instance later than 47.x builds
In Citrix ADM, ensure that the metrics collector service is available:
Navigate to Infrastructure > Network Function > Load Balancing > Services.
On the search bar, filter by Instance: (IP address) and Name: Citrix ADM.
Ensure if
adm_metric_collector_svc_<adm_receiver ip>
is available. The IP address can be either the Citrix ADM management IP or the agent IP.Ensure that this service is in UP status and running at Port 5563.
If you still cannot view the data, ensure that the collector service is bound to time series analytics profile in Citrix ADC.
Log on to Citrix ADC
Run the following command:
sh analytics profile ns_analytics_time_series_profile
If the collector indicates Down status:
Ensure if SNIP is configured.
If SNIP is not configured, you must configure SNIP. For more information, see Configuring SNIP.
Ensure that if ADC instance is reachable to Citrix ADM.
You can validate by doing a ping test. Run
ping -S <SNIP> <adm_receiver_ip>
Ensure that the traffic connectivity through telnet is able to connect the service.
If telnet is able to connect the service, then a firewall exists and is blocking the metric data flow. You must resolve the firewall block issue.
If no collector service is bound to time series analytics profile in Citrix ADC, the Collector is displayed as blank.
You must do an instance manual polling in Citrix ADM.
Navigate to Infrastructure > Network Function > Poll Now
Select the instance and click Start Polling.
If polling fails, add the collector service directly at Citrix ADC instance using the following commands:
add service adm_metric_collector_svc_<adm_receiver_ip> <adm_receiver_ip> HTTP 5563
unset analyticsprofile ns_analytics_time_series_profile -collectors
set analytics profile ns_analytics_time_series_profile -collectors adm_metric_collector_svc_<adm_receiver_ip> -metrics enabled -events enabled
The analytics time series profile is updated.
If the issue still persists even after performing all the mentioned troubleshooting steps, contact Citrix Support.