Close monitor connections 编辑
The Citrix ADC appliance sends probes to the services through the monitors bound to the services. By default, the monitor on the appliance and the physical server follow the complete handshake procedure even for monitor probes. However, this procedure adds overhead to the monitoring process and might not be always necessary.
For the TCP type monitor, you can configure the appliance to close a monitor-probe connection after receiving SYN-ACK from the service. To do so, set the value of the monitorConnectionClose parameter to RESET. If you want the monitor-probe connection to go through the complete procedure, set the value to FIN.
Note: The monitorConnectionClose setting is applicable only for type TCP and TCP-Default monitors.
To configure monitor-connection closure by using the command line interface:
At the command prompt, type:
set lb parameter -monitorConnectionClose <monitor_conn_close_option>
<!--NeedCopy-->