我知道有3种类型的联系卡。 A级,B,C(5V,3.3V,1.8V)

我知道我们可以从ATR中获得卡的电压要求。

我不明白的是,在读取卡的ATR信息之前,我们需要如何确定需要多少伏来喂养卡?

I know there are 3 types of contact cards. Class A,B,C (5V,3.3V,1.8V)

I know we can get the voltage requirement of card from it's ATR.

What I don't understand is how do we need to decide how many volts we need to feed the card just before the card's Atr information is read?

如果你对这篇内容有疑问,欢迎到本站社区发帖提问 参与讨论,获取更多帮助,或者扫码二维码加入 Web 技术交流群。

扫码二维码加入Web技术交流群

发布评论

需要 登录 才能够评论, 你可以免费 注册 一个本站的账号。

评论(1

千寻… 2025-02-03 18:19:06

不,电压类通常不会在ATR中编码(即使没有人限制将其放入历史字节中),因为如果您能够阅读ATR,则显然正在应用可接受的电压。

读取器的过程是应用最低电压,如果卡没有反应,请尝试下一个电压。请参阅关于电气工程的问题

No, the voltage class is not typically encoded in the ATR (even if nobody restricts to put it into the historical bytes), since if you are able to read the ATR you are obviously applying an acceptable voltage.

The process for a reader is, to apply the lowest voltage, and if the card does not react, try the next voltage. See this question on electrical engineering.