7044 44P Series Model 170
Dimensions
Height 490 mm 19.25 in.
Width 200 mm 7.9 in.
Width. 235 mm 9.25 in.
Depth 515 mm 20.25 in.
Weight
Minimum configuration 17.7 kg 39 lbs.
Maximum configuration 20.4 kg 45 lbs.
Electrical
Power source loading (typical in kVA) 0.23
Power source loading (maximum in
kVA)
0.40
Voltage range (V ac)
- US, World Trade, and Japan 100 to 127 or 200 to 240 (autoranging)
Frequency (hertz) 50 to 60
Thermal output (typical) 752 Btu/hr
Thermal output (maximum) 1368 Btu/hr
Power requirements (typical) 220 watts
Power requirements (maximum) 400 watts
Power factor - US, World Trade, Japan 0.98
Inrush current3 less than 60 amps at 120 V ac and at 240 V ac
Maximum altitude 2135 m (7000 ft.)
Temperature Requirements Operating
16 to 32亱C
(60 to 90亱F)
Non-Operating Power off
10 to 43亱C
(50 to 110亱F)
Humidity Requirements Operating Non-Operating Power off
(Noncondensing) 8 to 80% 8 to 80%
Wet Bulb 23亱C (73亱F) 27亱C (80亱F)
Noise Emissions1 Operating Idle
LWAd 5.5 bels 5.4 bels
LpAm N/A N/A
<LpA>m 38 dBA 37 dBA
Impulsive or prominent discrete tones No No
Clearances Front Back Left Right
Install/Air Flow2 76mm(3 in) 76mm(3 in) 0mm(0 in) 0mm(0 in)
Service Install so that it can be taken to an area providing 457mm(18 in) on the
front and 457mm(18 in) on the left side.
Footprint2 Width
235mm(9.25 in)
Depth
667mm(26.25 in)
1. See 乬Noise Emission Notes乭 on page 199 for definitions of noise emissions positions.
2. The amount of space needed by the unit during normal operation is indicated by the footprint dimensions.
3. Inrush currents occur only at initial application of power, no inrush occurs during normal power off-on cycle.
4. Width measurement With feet extended.