关于event.log中Missing Drive HP问题
各位大侠:请帮忙确认一下HP系统中event.log里告警是否存在运行风险
谢谢了。
event告警如下:
Event data from monitor:
Event Time..........: Fri Jan 21 13:29:45 2011
Severity............: MINORWARNING
Monitor.............: RemoteMonitor
Event #.............: 213
System..............: scp
Summary:
Disk Array at hardware path 0/4/0/0.8.0.255.6.14.0 : Missing Drive HP
36.4G ST336753FC ## 3HX08848.
Description of Error:
One or more member drives are missing.
Probable Cause / Recommended Action:
Re-install the missing member drive or drives.
Additional Event Data:
System IP Address...: 139.100.168.112
Event Id............: 0x4d3919c900000003
Monitor Version.....: B.01.00
Event Class.........: I/O
Client Configuration File...........:
/var/stm/config/tools/monitor/default_RemoteMonitor.clcfg
Client Configuration File Version...: A.01.01
Qualification criteria met.
Number of events..: 1
Associated OS error log entry id(s):
None
Additional System Data:
System Model Number.............: 9000/800/N4000-44
EMS Version.....................: A.03.20
STM Version.....................: A.44.00
Latest information on this event:
http://docs.hp.com/hpux/content/ ... moteMonitor.htm#213
如果你对这篇内容有疑问,欢迎到本站社区发帖提问 参与讨论,获取更多帮助,或者扫码二维码加入 Web 技术交流群。
绑定邮箱获取回复消息
由于您还没有绑定你的真实邮箱,如果其他用户或者作者回复了您的评论,将不能在第一时间通知您!
发布评论
评论(3)
2楼的好专业啊
谢谢!问题已经解决,是磁盘阵列中磁盘问题,更换后,正常。
看log的说明是需要重新插拔去识别的,但是从硬件路径看好像是存储上的盘,不是本机的盘呀。那就执行ioscan去看看这个盘的状态,在到存储上看看这个盘的状态,如果都没有问题的话,看看是不是前几天做过插拔线之类的操作了。