我的RX4640硬盘怎么了
>------------ Event Monitoring Service Event Notification ------------<
Notification Time: Sun Jun 13 22:56:00 2010
test sent Event Monitor notification information:
/storage/events/disks/default/0_1_1_0.1.0 is >= 1.
Its current value is CRITICAL(5).
Event data from monitor:
Event Time..........: Sun Jun 13 22:56:00 2010
Severity............: CRITICAL
Monitor.............: disk_em
Event #.............: 18
System..............: test
Summary:
Disk at hardware path 0/1/1/0.1.0 : Drive is not responding.
Description of Error:
The hardware did not respond to the request by the driver. The I/O request
was not completed.
Probable Cause / Recommended Action:
The I/O request that the monitor made to this device failed because the
device timed-out. Check cables, power supply, ensure the drive is powered
ON, and if needed contact your HP support representative to check the
drive.
Additional Event Data:
System IP Address...: 10.0.0.2
System IP Address...: 172.16.10.2
Event Id............: 0x4c14f18000000000
Monitor Version.....: B.01.01
Event Class.........: I/O
Client Configuration File...........:
/var/stm/config/tools/monitor/default_disk_em.clcfg
Client Configuration File Version...: A.01.00
Qualification criteria met.
Number of events..: 1
Associated OS error log entry id(s):
0x4c14f18000000000
Additional System Data:
System Model Number.............: ia64 hp SERVER RX4640
OS Version......................: B.11.23
STM Version.....................: C.53.00
EMS Version.....................: A.04.20
Latest information on this event:
http://docs.hp.com/hpux/content/hardware/ems/disk_em.htm
v-v-v-v-v-v-v-v-v-v-v-v-v D E T A I L S v-v-v-v-v-v-v-v-v-v-v-v-v
Component Data:
Physical Device Path...: 0/1/1/0.1.0
Device Class...........: Disk
Inquiry Vendor ID......: HP 73.4G
Inquiry Product ID.....: MAX3073NC
Firmware Version.......: HPC1
Serial Number..........: X1024119 0626
Product/Device Identification Information:
Logger ID.........: sdisk
Product Identifier: SCSI Disk
Product Qualifier.: HP73.4GMAX3073NC
SCSI Target ID....: 0x01
SCSI LUN..........: 0x00
I/O Log Event Data:
Driver Status Code..................: 0x0000007E
Length of Logged Hardware Status....: 4 bytes.
Offset to Logged Manager Information: 8 bytes.
Length of Logged Manager Information: 34 bytes.
SCSI Command Data Block:
Command Data Block Contents:
0x0000: 28 00 00 0F A0 32 00 00 02 00
Command Data Block Fields (10-byte fmt):
Command Operation Code...(0x2..: READ
Logical Unit Number..............: 0
DPO Bit..........................: 0
FUA Bit..........................: 0
Relative Address Bit.............: 0
Logical Block Address............: 1024050 (0x000FA032)
Transfer Length..................: 2 (0x0002)
Manager-Specific Data Fields:
Request ID.............: 0x02CAB16C
Data Residue...........: 0x00000400
CDB status.............: 0x00000200
Sense Status...........: 0x00000000
Bus ID.................: 0x02
Target ID..............: 0x01
LUN ID.................: 0x00
Sense Data Length......: 0x00
Q Tag..................: 0xF7
Retry Count............: 0
>---------- End Event Monitoring Service Event Notification ----------<
不知是不是坏了,
如果你对这篇内容有疑问,欢迎到本站社区发帖提问 参与讨论,获取更多帮助,或者扫码二维码加入 Web 技术交流群。
绑定邮箱获取回复消息
由于您还没有绑定你的真实邮箱,如果其他用户或者作者回复了您的评论,将不能在第一时间通知您!
发布评论
评论(9)
建议换掉,有需要可联系我
坏了,换吧
换吧
没可能是背板坏了
因为你只有这一个硬盘有问题啊
有没有可能是背板坏了
挂了,最好赶紧换掉.
应该是坏了,换吧
本帖最后由 maoyh 于 2010-07-06 17:18 编辑
[hnsh-db:/var/adm/syslog]diskinfo /dev/rdsk/c2t1d0
diskinfo: can't SIOC_INQUIRY /dev/rdsk/c2t1d0: No such device or address
[hnsh-db:/var/adm/syslog]diskinfo /dev/rdsk/c3t0d0
SCSI describe of /dev/rdsk/c3t0d0:
vendor: HP 73.4G
product id: MAX3073NC
type: direct access
size: 71687369 Kbytes
bytes per sector: 512
[hnsh-db:/var/adm/syslog]vgdisplay -v /dev/vg00
--- Volume groups ---
VG Name /dev/vg00
VG Write Access read/write
VG Status available
Max LV 255
Cur LV 9
Open LV 9
Max PV 16
Cur PV 2
Act PV 2
Max PE per PV 4328
VGDA 4
PE Size (Mbytes) 16
Total PE 8646
Alloc PE 4722
Free PE 3924
Total PVG 0
Total Spare PVs 0
Total Spare PVs in use 0
--- Logical volumes ---
LV Name /dev/vg00/lvol1
LV Status available/stale
LV Size (Mbytes) 304
Current LE 19
Allocated PE 38
Used PV 2
--- Physical volumes ---
PV Name /dev/dsk/c2t1d0s2
PV Status unavailable
Total PE 4318
Free PE 1957
Autoswitch On
PV Name /dev/dsk/c3t0d0s2
PV Status available
Total PE 4328
Free PE 1967
Autoswitch On
[hnsh-db:/etc]ioscan -fnC disk
Class I H/W Path Driver S/W State H/W Type Description
============================================================================
disk 0 0/0/3/0.0.0.0 sdisk CLAIMED DEVICE TEAC DV-28E-N
/dev/dsk/c0t0d0 /dev/rdsk/c0t0d0
disk 1 0/1/1/0.1.0 sdisk NO_HW DEVICE HP 73.4GMAX3073NC
/dev/dsk/c2t1d0 /dev/rdsk/c2t1d0
/dev/dsk/c2t1d0s1 /dev/rdsk/c2t1d0s1
/dev/dsk/c2t1d0s2 /dev/rdsk/c2t1d0s2
/dev/dsk/c2t1d0s3 /dev/rdsk/c2t1d0s3
disk 2 0/1/1/1.0.0 sdisk CLAIMED DEVICE HP 73.4GMAX3073NC
/dev/dsk/c3t0d0 /dev/rdsk/c3t0d0
/dev/dsk/c3t0d0s1 /dev/rdsk/c3t0d0s1
/dev/dsk/c3t0d0s2 /dev/rdsk/c3t0d0s2
状态都无效,应该是坏了
看看其他状态,ioscanvgdisplaydiskinfo等等,最后可以做一个dd测试,dd通过的话应该没有问题~