hp-ux11.31更改instance号
这是网友“星期八”指导的方法,可惜数据迁移很紧,连续干了几个通宵,没时间试,哪位大哥如果有时间不妨试一试,看看效果怎么样?
在这里还是要谢谢“星期八”这位大哥!
方法1:
例子是把disk88改为disk288
iobind - change driver bound to a LUN
io_redirect_dsf - redirect device special file to a new device
iobind -H 64000/0xfa00/0xb -M esdisk -I 288 (-H 后面是原disk88的H/W PATH),重起后生效,重起之前可以用ioscan –B查看修改的状态,或者用ioscan –r -H device_hw_path取消修改。
---------------------------------------------------------
办法2:是用ioinit
Note: PHKL_36333 and PHCO_36315
需要这两个补丁才能执行ioinit
下面是是disk68改为disk53
# ioscan -fnNkCdis
# ioscan -fnkCdisk
# ioscan -m dsf /dev/disk/disk62
# ioscan -m dsf /dev/disk/disk63
# ioscan -m dsf /dev/disk/disk68
# cd /tmp
# ioscan -kNf | grep ^disk | awk '{printf "%s %s %sn",$3,$1,$2}' > infile
# ioscan -kf | grep ^disk | awk '{printf "%s %s %sn",$3,$1,$2}' >> infile
vi infile
然后把51改为68
# ioinit -f ./infile
# ioscan -fnNkCdisk
检查下
# rmsf /dev/disk/disk62 /dev/rdisk/disk62
# rmsf /dev/disk/disk63 /dev/rdisk/disk63
# rmsf /dev/disk/disk68 /dev/rdisk/disk68
然后你自己再确认下
我现在不比以前,有实验机,可以先给你测试下
这只能你自己测试了
例子是把disk62/disk63/disk68 修改为 disk51/disk52/disk53
如果你对这篇内容有疑问,欢迎到本站社区发帖提问 参与讨论,获取更多帮助,或者扫码二维码加入 Web 技术交流群。
绑定邮箱获取回复消息
由于您还没有绑定你的真实邮箱,如果其他用户或者作者回复了您的评论,将不能在第一时间通知您!
发布评论
评论(4)
学习一下。。
学习
V3下没有试过,有环境试试看。
我只知道第二种方法,但是和你的也不太一样,在infile文件中改完instance number后,要把/etc/ioconfig移走,然后重启
(ioinit)#/sbin/ioinit -C
(ioinit)#/sbin/ioinit -f /infile -r
没有试过,不知道我这个行不行