有台va7410 前段时间坏了一块硬盘,前天去把盘拔下来换了一块,但是截止到今天,阵列还是一直有一个警告,如下:
WARNING: The host indicated that hot spare space reservation was desired, but the space left unallocated was insufficient to provide the reservation.
之前坏盘的时候,也有这个警告,我觉得是坏盘引起的,现在armdsp -a 看,所有的设备status都是good.这个应该是警告说没有hotspare空间,请问我该怎么操作呢。
命令结果如下:
Vendor ID:______________________________HP
Product ID:_____________________________A6189A
Array World Wide Name:__________________50060b000014e4e5
Array Serial Number:____________________00SG223J0121
Alias:__________________________________WG
Software Revision:______________________01.07.00 - 0256 - 030925
Command execution timestamp:____________Sep 29, 2009 5:17:51 PM
------------------------------------------------------------
ARRAY INFORMATION
Array Status:_________________________Warning
Firmware Revision:____________________38370HP20P1007041848
Product Revision:_____________________HP20
Last Event Log Entry for Page 1:______347986056
ENCLOSURES
Enclosure at M
Enclosure ID__________________________0
Enclosure Status______________________Good
Enclosure Type________________________HP StorageWorks Virtual Array 7400
Node WWN______________________________50060b000014e4e5
FRU HW COMPONENT IDENTIFICATION ID STATUS
===========================================================================
M Enclosure 00SG223J0121 Good
M/P1 Power Supply 94050ME00111 Good
M/P2 Power Supply 94020LC01714 Good
M/MP1 MidPlane 000601310466 Good
M/C2 Controller 00PR05B50941 Good
M/C2.H1 Host Port <none> Good
M/C2.J1 BackEnd Port <none> Good
M/C2.B1 Battery 25875:MOLTECHPS:NI2040:2001/12/ Good
M/C2.PM1 Processor HP:A6189A:HP20 Good
M/C2.M1 DIMM 512 Good
M/C2.M2 DIMM 512 Good
M/C1 Controller 00PR05B51584 Good
M/C1.H1 Host Port <none> Good
M/C1.J1 BackEnd Port <none> Good
M/C1.B1 Battery 7413:MOLTECHPS:NI2040:2001/5/1 Good
M/C1.PM1 Processor HP:A6189A:HP20 Good
M/C1.M1 DIMM 512 Good
M/C1.M2 DIMM 512 Good
M/D1 Disk 3EK2TNJM Good
M/D2 Disk 3EK0J34B Good
M/D3 Disk 3EK1NXEV Good
M/D4 Disk 3HZY3T67 Good
M/D5 Disk 3EK1NWXN Good
M/D6 Disk 3EK1NQR6 Good
M/D7 Disk 3EK0LQAT Good
M/D8 Disk 3HZ605ZB Good
M/D9 Disk 3HZ6Q5X9 Good
M/D10 Disk 3EK1NXTY Good
M/D11 Disk 3EK1NT51 Good
M/D12 Disk 3EK1NXCP Good
M/D13 Disk 3HZ658B4 Good
M/D14 Disk 3HZ63SE0 Good
M/D15 Disk 3HZ654GJ Good
LUNS
LUN 0:
Redundancy Group:_____________________1
Active:_______________________________True
Data Capacity:________________________100 MB
WWN:__________________________________60060b000014e4e5000000000000001d
Number Of Business Copies:____________0
LUN 1:
Redundancy Group:_____________________1
Active:_______________________________True
Data Capacity:________________________100 GB
WWN:__________________________________60060b000014e4e5000100000000001e
Number Of Business Copies:____________0
LUN 2:
Redundancy Group:_____________________2
Active:_______________________________True
Data Capacity:________________________100 GB
WWN:__________________________________60060b000014e4e50002000000000022
Number Of Business Copies:____________0
LUN 3:
Redundancy Group:_____________________1
Active:_______________________________True
Data Capacity:________________________140 GB
WWN:__________________________________60060b000014e4e50003000000000020
Number Of Business Copies:____________0
LUN 4:
Redundancy Group:_____________________2
Active:_______________________________True
Data Capacity:________________________150 GB
WWN:__________________________________60060b000014e4e50004000000000021
Number Of Business Copies:____________0
CAPACITY Totals for Redundancy Group 1:
REGULAR LUNs:_________________________240.097 GB
BUSINESS COPIES:______________________0 bytes
CAPACITY Totals for Redundancy Group 2:
REGULAR LUNs:_________________________250 GB
BUSINESS COPIES:______________________0 bytes
CAPACITY USAGE
Total Disk Enclosures:________________1
Redundancy Group:_____________________1
Total Disks:________________________8
Total Physical Size:________________534.057 GB
Allocated to Regular LUNs:__________240.097 GB
Allocated as Business Copies:_______0 bytes
Used as Active Hot Spare:___________0 bytes
Used for Redundancy:________________220.018 GB
Unallocated (Available for LUNs):___73.941 GB
Redundancy Group:_____________________2
Total Disks:________________________6
Total Physical Size:________________400.543 GB
Allocated to Regular LUNs:__________250 GB
Allocated as Business Copies:_______0 bytes
Used as Active Hot Spare:___________0 bytes
Used for Redundancy:________________150.543 GB
Unallocated (Available for LUNs):___0 bytes
Used by Non-Included Disks:___________66.757 GB
SUB-SYSTEM SETTINGS
RAID Level:___________________________HPAutoRAID
Auto Format Drive:____________________On
Hang Detection:_______________________On
Capacity Depletion Threshold:_________100%
Queue Full Threshold Maximum:_________4096
Enable Optimize Policy:_______________True
Enable Manual Override:_______________False
Manual Override Destination:__________False
Read Cache Disable:___________________False
Rebuild Priority:_____________________Low
Security Enabled:_____________________False
Shutdown Completion:__________________0
Subsystem Type ID:____________________1
Unit Attention:_______________________True
Volume Set Partition (VSpart):________False
Write Cache Enable:___________________True
Write Working Set Interval:___________8640
Enable Prefetch:______________________True
Disable Secondary Path Presentation:__False
RESILIENCY SETTINGS
Simplified Resiliency Setting:________Normal Performance (Default)
Enable Secure Mode:___________________True
Disable NVRAM on UPS Absent:__________False
Disable NVRAM on WCE False:___________False
Disable Read Hits:____________________False
Force Unit Access Response:___________1
Lock Write Cache On:__________________True
Performance Goal Configuration:_______Normal Performance
Resiliency Threshold:_________________4
Single Controller Warning:____________True
DISK SETTINGS
Auto Include:_________________________On
Auto Rebuild:_________________________On
Hot Spare:____________________________Automatic
Max Drives per Loop Pair:_____________105
Max Drives per Subsystem:_____________105
ENCLOSURE SETTINGS
Max Enclosures per Loop Pair:_________6
Max Enclosures per Subsystem:_________6
LUN SETTINGS
LUN Creation Limit:___________________1024
Maximum LUN Creation Limit:___________1024
Migrating Write Destination:__________False
SCRUB SETTINGS
Scrub Restart Period:_________________7190 minutes
Scrub State:__________________________Stopped, host activity detected
OPERATIONS IN PROGRESS
None
WARNINGS
WARNING: The host indicated that hot spare space reservation was desired, but the space left unallocated was insufficient to provide the reservation.
如果你对这篇内容有疑问,欢迎到本站社区发帖提问 参与讨论,获取更多帮助,或者扫码二维码加入 Web 技术交流群。
绑定邮箱获取回复消息
由于您还没有绑定你的真实邮箱,如果其他用户或者作者回复了您的评论,将不能在第一时间通知您!
发布评论
评论(5)
看到你的VA有设置Hot Spare为Automatic,出现那个Warning是因为阵列没有足够的空间符合定义的spare空间的要求(假设所有盘都为73G,如果阵列的盘数少于等于15个,那就需要73GB作为spare空间;如果阵列的盘数大于15个,那就需要2X73GB作为spare空间)。当然如果你把spare的Automatic设置禁止的话,我相信不会再出现那个Warning的,但这不是最好的方法,毕竟有hotspare空间比较安全。而我看到你的2个RG的可用空间不多(Active Hot Spare都没有),所以你根据前面要求加盘就行了(要保留数据的话可能需要扩容了)。
PS: 原来没有自动加进去,呵~电气的东西,摸不着脾气呢。。
[ 本帖最后由 lbseraph 于 2009-9-30 09:08 编辑 ]
呵呵
Used as Active Hot Spare:___________0 bytes
看见了么
经过检查,发现我更换的那块盘没有正常的include进去,虽然autoinclude是on的状态,于是我手工进行了armcfg -D M/D2 -a array 的操作,之后就正常了
友情帮顶