有台va7410  前段时间坏了一块硬盘,前天去把盘拔下来换了一块,但是截止到今天,阵列还是一直有一个警告,如下:

  WARNING: The host indicated that hot spare space reservation was desired, but the space left unallocated was insufficient to provide the reservation.

之前坏盘的时候,也有这个警告,我觉得是坏盘引起的,现在armdsp -a 看,所有的设备status都是good.这个应该是警告说没有hotspare空间,请问我该怎么操作呢。

命令结果如下:

Vendor ID:______________________________HP
Product ID:_____________________________A6189A
Array World Wide Name:__________________50060b000014e4e5
Array Serial Number:____________________00SG223J0121
Alias:__________________________________WG
Software Revision:______________________01.07.00 - 0256  - 030925
Command execution timestamp:____________Sep 29, 2009 5:17:51 PM
------------------------------------------------------------
ARRAY INFORMATION
  Array Status:_________________________Warning
  Firmware Revision:____________________38370HP20P1007041848
  Product Revision:_____________________HP20
  Last Event Log Entry for Page 1:______347986056
ENCLOSURES
Enclosure at M
  Enclosure ID__________________________0
  Enclosure Status______________________Good
  Enclosure Type________________________HP StorageWorks Virtual Array 7400
  Node WWN______________________________50060b000014e4e5
  FRU       HW COMPONENT   IDENTIFICATION                   ID STATUS
  ===========================================================================
  M         Enclosure      00SG223J0121                        Good
  M/P1      Power Supply   94050ME00111                        Good
  M/P2      Power Supply   94020LC01714                        Good
  M/MP1     MidPlane       000601310466                        Good
  M/C2      Controller     00PR05B50941                        Good
  M/C2.H1   Host Port      <none>                              Good
  M/C2.J1   BackEnd Port   <none>                              Good
  M/C2.B1   Battery        25875:MOLTECHPS:NI2040:2001/12/     Good
  M/C2.PM1  Processor      HP:A6189A:HP20                      Good
  M/C2.M1   DIMM           512                                 Good
  M/C2.M2   DIMM           512                                 Good
  M/C1      Controller     00PR05B51584                        Good
  M/C1.H1   Host Port      <none>                              Good
  M/C1.J1   BackEnd Port   <none>                              Good
  M/C1.B1   Battery        7413:MOLTECHPS:NI2040:2001/5/1      Good
  M/C1.PM1  Processor      HP:A6189A:HP20                      Good
  M/C1.M1   DIMM           512                                 Good
  M/C1.M2   DIMM           512                                 Good
  M/D1      Disk           3EK2TNJM                            Good
  M/D2      Disk           3EK0J34B                            Good
  M/D3      Disk           3EK1NXEV                            Good
  M/D4      Disk           3HZY3T67                            Good
  M/D5      Disk           3EK1NWXN                            Good
  M/D6      Disk           3EK1NQR6                            Good
  M/D7      Disk           3EK0LQAT                            Good
  M/D8      Disk           3HZ605ZB                            Good
  M/D9      Disk           3HZ6Q5X9                            Good
  M/D10     Disk           3EK1NXTY                            Good
  M/D11     Disk           3EK1NT51                            Good
  M/D12     Disk           3EK1NXCP                            Good
  M/D13     Disk           3HZ658B4                            Good
  M/D14     Disk           3HZ63SE0                            Good
  M/D15     Disk           3HZ654GJ                            Good
LUNS
LUN 0:
  Redundancy Group:_____________________1
  Active:_______________________________True
  Data Capacity:________________________100 MB
  WWN:__________________________________60060b000014e4e5000000000000001d
  Number Of Business Copies:____________0
LUN 1:
  Redundancy Group:_____________________1
  Active:_______________________________True
  Data Capacity:________________________100 GB
  WWN:__________________________________60060b000014e4e5000100000000001e
  Number Of Business Copies:____________0
LUN 2:
  Redundancy Group:_____________________2
  Active:_______________________________True
  Data Capacity:________________________100 GB
  WWN:__________________________________60060b000014e4e50002000000000022
  Number Of Business Copies:____________0
LUN 3:
  Redundancy Group:_____________________1
  Active:_______________________________True
  Data Capacity:________________________140 GB
  WWN:__________________________________60060b000014e4e50003000000000020
  Number Of Business Copies:____________0
LUN 4:
  Redundancy Group:_____________________2
  Active:_______________________________True
  Data Capacity:________________________150 GB
  WWN:__________________________________60060b000014e4e50004000000000021
  Number Of Business Copies:____________0
CAPACITY Totals for Redundancy Group 1:
  REGULAR LUNs:_________________________240.097 GB
  BUSINESS COPIES:______________________0 bytes
CAPACITY Totals for Redundancy Group 2:
  REGULAR LUNs:_________________________250 GB
  BUSINESS COPIES:______________________0 bytes
CAPACITY USAGE
  Total Disk Enclosures:________________1
  Redundancy Group:_____________________1
    Total Disks:________________________8
    Total Physical Size:________________534.057 GB
    Allocated to Regular LUNs:__________240.097 GB
    Allocated as Business Copies:_______0 bytes
    Used as Active Hot Spare:___________0 bytes
    Used for Redundancy:________________220.018 GB
    Unallocated (Available for LUNs):___73.941 GB
  Redundancy Group:_____________________2
    Total Disks:________________________6
    Total Physical Size:________________400.543 GB
    Allocated to Regular LUNs:__________250 GB
    Allocated as Business Copies:_______0 bytes
    Used as Active Hot Spare:___________0 bytes
    Used for Redundancy:________________150.543 GB
    Unallocated (Available for LUNs):___0 bytes
  Used by Non-Included Disks:___________66.757 GB
SUB-SYSTEM SETTINGS
  RAID Level:___________________________HPAutoRAID
  Auto Format Drive:____________________On
  Hang Detection:_______________________On
  Capacity Depletion Threshold:_________100%
  Queue Full Threshold Maximum:_________4096
  Enable Optimize Policy:_______________True
  Enable Manual Override:_______________False
  Manual Override Destination:__________False
  Read Cache Disable:___________________False
  Rebuild Priority:_____________________Low
  Security Enabled:_____________________False
  Shutdown Completion:__________________0
  Subsystem Type ID:____________________1
  Unit Attention:_______________________True
  Volume Set Partition (VSpart):________False
  Write Cache Enable:___________________True
  Write Working Set Interval:___________8640
  Enable Prefetch:______________________True
  Disable Secondary Path Presentation:__False
RESILIENCY SETTINGS
  Simplified Resiliency Setting:________Normal Performance (Default)
  Enable Secure Mode:___________________True
  Disable NVRAM on UPS Absent:__________False
  Disable NVRAM on WCE False:___________False
  Disable Read Hits:____________________False
  Force Unit Access Response:___________1
  Lock Write Cache On:__________________True
  Performance Goal Configuration:_______Normal Performance
  Resiliency Threshold:_________________4
  Single Controller Warning:____________True
DISK SETTINGS
  Auto Include:_________________________On
  Auto Rebuild:_________________________On
  Hot Spare:____________________________Automatic
  Max Drives per Loop Pair:_____________105
  Max Drives per Subsystem:_____________105
ENCLOSURE SETTINGS
  Max Enclosures per Loop Pair:_________6
  Max Enclosures per Subsystem:_________6
LUN SETTINGS
  LUN Creation Limit:___________________1024
  Maximum LUN Creation Limit:___________1024
  Migrating Write Destination:__________False
SCRUB SETTINGS
  Scrub Restart Period:_________________7190 minutes
  Scrub State:__________________________Stopped, host activity detected
OPERATIONS IN PROGRESS
  None
WARNINGS
  WARNING: The host indicated that hot spare space reservation was desired, but the space left unallocated was insufficient to provide the reservation.

如果你对这篇内容有疑问,欢迎到本站社区发帖提问 参与讨论,获取更多帮助,或者扫码二维码加入 Web 技术交流群。

扫码二维码加入Web技术交流群

发布评论

需要 登录 才能够评论, 你可以免费 注册 一个本站的账号。

评论(5

-残月青衣踏尘吟 2022-08-29 15:00:16

看到你的VA有设置Hot Spare为Automatic,出现那个Warning是因为阵列没有足够的空间符合定义的spare空间的要求(假设所有盘都为73G,如果阵列的盘数少于等于15个,那就需要73GB作为spare空间;如果阵列的盘数大于15个,那就需要2X73GB作为spare空间)。当然如果你把spare的Automatic设置禁止的话,我相信不会再出现那个Warning的,但这不是最好的方法,毕竟有hotspare空间比较安全。而我看到你的2个RG的可用空间不多(Active Hot Spare都没有),所以你根据前面要求加盘就行了(要保留数据的话可能需要扩容了)。

PS: 原来没有自动加进去,呵~电气的东西,摸不着脾气呢。。

[ 本帖最后由 lbseraph 于 2009-9-30 09:08 编辑 ]

自演自醉 2022-08-29 12:31:02

呵呵

温柔少女心 2022-08-29 07:35:56

Used as Active Hot Spare:___________0 bytes

看见了么

嘿咻 2022-08-29 02:05:42

经过检查,发现我更换的那块盘没有正常的include进去,虽然autoinclude是on的状态,于是我手工进行了armcfg -D M/D2 -a array 的操作,之后就正常了