RX4640 硬盘坏了,怎么办呢?
抓的信息,换硬盘是不是直接插上就好了呢?
db2:/dev# sautil /dev/ciss4
******************************************************************************
**** ****
**** S A U T I L S u p p o r t U t i l i t y ****
**** ****
**** for the HP SmartArray RAID Controller Family ****
**** ****
**** version A.02.09 ****
**** ****
**** (C) Copyright 2003-2005 Hewlett-Packard Development Company, L.P. ****
******************************************************************************
---- DRIVER INFORMATION ------------------------------------------------------
Driver State........................ READY
---- CONTROLLER INFORMATION --------------------------------------------------
Controller Product Number........... A9890A
Controller Product Name............. HP PCI-X SmartArray 6402
Hardware Path....................... 0/2/1/0/4/0
Serial Number....................... P57820RXQSE0NM
Device File......................... /dev/ciss4
Hardware Revision................... 'B'
Boot Block Revision................. 3.86
Firmware Revision (running)......... 2.34
Firmware Revision (in ROM).......... 2.34
Firmware Revision (inactive)........ 2.34
# of Logical Drives................. 1
# of Physical Disks Configured...... 2
# of Physical Disks Detected........ 1
Logical Drive Rebuild Priority...... 0 (low)
Array Capacity Expansion Priority... 0 (low)
Auto-Fail Missing Disks at Boot..... disabled
SCSI Transfer Detection Mode........ Auto Detect
---- ARRAY ACCELERATOR (CACHE) INFORMATION -----------------------------------
Array Accelerator Board Present?.... yes
Cache Configuration Status.......... cache enabled
Cache Ratio......................... 50% Read / 50% Write
Total Cache Size (MB)............... 128
Read Cache........................ 064
Write Cache....................... 064
Transfer Buffer................... 000
Battery Pack Count.................. 2
Battery Status (pack #1)............ ok
Battery Status (pack #2)............ ok
---- LOGICAL DRIVE SUMMARY ---------------------------------------------------
# RAID Size Status
0 1+0 70001 MB USING INTERIM RECOVERY MODE
---- SCSI DEVICE SUMMARY -----------------------------------------------------
Location Ch ID Type Capacity Status
N/A 1 1 N/A N/A FAILED
internal 2 0 DISK 73.4 GB OK
---- SCSI BUS SUMMARY --------------------------------------------------------
External Internal
Ch LVD_Mode Connector Connector
1 YES - YES
2 YES - YES
---- LOGICAL DRIVE 0 ---------------------------------------------------------
Logical Drive Device File........... c4t0d0
Fault Tolerance Mode................ RAID 1+0 (Disk Mirroring)
Logical Drive Size.................. 70001 MB
Logical Drive Status................ USING INTERIM RECOVERY MODE
# of Participating Physical Disks... 2
Participating Physical Disk(s)...... Ch:ID
1: 1 <-- NOT RESPONDING
2: 0
Participating Spare Disk(s)......... Ch:ID
none
Stripe Size......................... 128 KB
Logical Drive Cache Status.......... cache enabled
Configuration Signature............. 0xA01473A2
Media Exchange Detected?............ no
---- SCSI DEVICE 2:0 [DISK] --------------------------------------------------
Connector Location............................... internal
Channel Number................................... 2
SCSI ID.......................................... 0
Device Type...................................... DISK
Disk Capacity.................................... 73.4 GB
Device Status.................................... OK
Device Vendor ID................................. HP 73.4G
Device Product ID................................ MAX3073NC
Device Serial Number............................. X1002701 0542
Device Firmware Version.......................... HPC1
SCSI Transfer Rate (actual)...................... Ultra-320
Reserved Area (cfg/status info).................. 557.1 KB (0.6 MB)
Block Size (bytes/sector)........................ 512 bytes
M&P Data Stamped?................................ no
Last Failure Reason.............................. none
Physical Disk Flags:
Disk present and operational................... yes
Non-disk device detected....................... no
Wide SCSI transfer enabled..................... yes
Synchronous (Fast/Ultra) transfer enabled...... yes
Narrow disk tray detected...................... no
Wide transfer failed, reverted to narrow....... no
Ultra SCSI transfer enabled.................... yes
Ultra-2 SCSI transfer enabled.................. yes
S.M.A.R.T. supported........................... yes
S.M.A.R.T. errors (in factory M&P data)........ no
S.M.A.R.T. enabled............................. yes
S.M.A.R.T. errors (in powerup M&P data)........ no
Attached to external channel................... no
Configured in a logical drive.................. yes
Configured as a spare disk..................... no
Disk write cache enabled at spin up............ no
Running in DT clocking mode.................... yes
Supports DT clocking mode only................. no
Supports DT and ST clocking modes.............. yes
Running in U320 mode........................... yes
Packetized SCSI supported...................... yes
Supports redundant controller operation........ yes
Disk write cache enabled in current page....... no
Disk write cache disabled in default page...... no
QAS capable (U320 only)........................ yes
Currently running QAS (U320 only).............. yes
---- DIAGRAM OF EXTERNAL CONNECTORS ON BRACKET -------------------------------
========---========
| |
| U320 <--- LOOK FOR THIS LOGO
| / |
| <- |
| / |
| |
| * * |
| * * * * |
(Ch A1)---> * * * * <--- (Ch A2)
| * * * * |
| * * |
| |
| |
| |
| |
| |
| |
| |
| |
| |
~ ~ ~ ~ ~
******************************************************************************
**** End of SAUTIL Output ****
******************************************************************************
db2:/dev#
如果你对这篇内容有疑问,欢迎到本站社区发帖提问 参与讨论,获取更多帮助,或者扫码二维码加入 Web 技术交流群。
绑定邮箱获取回复消息
由于您还没有绑定你的真实邮箱,如果其他用户或者作者回复了您的评论,将不能在第一时间通知您!
发布评论
评论(9)
22页 描述比较详细,看好了,直接拔了换
你看你上面的显示:
---- LOGICAL DRIVE 0 ---------------------------------------------------------
Logical Drive Device File........... c4t0d0
Fault Tolerance Mode................ RAID 1+0 (Disk Mirroring)
Logical Drive Size.................. 70001 MB
Logical Drive Status................ USING INTERIM RECOVERY MODE
。。。
这个mirror是这个卡硬件做的,在OS的下层,所以不需要MirrorDisk/UX(OS层的),所以不必管它。只要看看那阵列的手册的如何换就可。看盘上的指示灯(对手册),就确定哪个坏了,照手册步骤换之……不是很复杂,try it
装操作系统的时候是先划完RAID0+1才开始装的,原意味是用MirrorDisk/UX做的,swlist -l bundle查看后,压根没发现这个软件,因此确定为硬件RAID,找了个测试机,安装了下HP-UNIX,在开始安装前,提示先配置RAID的。原来的大哥辞职了,现在出现这个问题。哎。其它品牌的一般直接插入新硬盘就慢慢同步了,不知道HP的怎么样,关键是系统内使用的所有HP的设备压根没坏过,打电话说过保了,哎这方面的实际经验少。其它的服务器硬盘估计都换了个遍了。
[ 本帖最后由 漫天飞虹 于 2009-9-4 16:31 编辑 ]
43页开始
貌似直接插盘完事
Controller Product Number........... A9890A
Controller Product Name............. HP PCI-X SmartArray 6402
扩展卡,看看这个的user guide
http://h20000.www2.hp.com/bizsup ... p;lang=en&cc=us
是的。Controller Product Name............. HP PCI-X SmartArray 6402
sautil(1M) sautil(1M)
NAME
sautil - Support Utility for the HP SmartArray RAID Controller Family
ciss4?是个raid控制器吗?
bash-2.04# sautil /dev/ciss4
******************************************************************************
**** ****
**** S A U T I L S u p p o r t U t i l i t y ****
**** ****
**** for the HP SmartArray RAID Controller Family ****
**** ****
**** version A.02.05 ****
**** ****
**** (C) Copyright 2003, 2004 Hewlett-Packard Development Company, L.P. ****
******************************************************************************
sautil: Unrecognized device file specified: "/dev/ciss4"
sautil: Error - File open failed
sautil: No such device, errno=19
RAID SA device files (/dev/cissX) found using "/usr/sbin/ioscan -kfnd ciss":
Run "sautil run_startup_script" if you suspect that the device file is missing or corrupted.
Run "sautil" to view usage screen.
bash-2.04# /usr/sbin/ioscan -kfnd ciss
bash-2.04#
是不是没有raid卡?
机器本身似没啥特殊,看看那文档吧——后面内容
============================================
编辑一下啊:
抱歉!这个有点误导。LZ这个是扩展卡接的盘,不是本机那俩盘,这个PDF不适用。